Measurements | |
Dual element transducer measurement mode | Time interval from a precision delay after the excitation pulse to the first echo |
THRU-COAT® measurement | Measurement of true metal and coating thicknesses with a single back-wall echo (with D7906-SM and D7908 transducers) |
Thru-Paint Echo-to-Echo | Time interval between two successive back-wall echoes to eliminate paint or coating thickness |
Single element transducer measurement modes | Mode 1: Time interval between the excitation pulse and the first back-wall echo Mode 2: Time interval between the delay line echo and the first back-wall echo (with delay or immersion transducers) Mode 3: Time interval between successive back-wall echoes following the first interface echo after the excitation pulse (with delay line or immersion transducers) Oxide: optional Multilayer mode: optional |
`Thickness range | 0.080 mm to 635.00 mm (0.003 in. to 25.000 in.) depending on material, transducer surface conditions, temperature, and selected configuration |
Material velocity range | 0.508 mm/μs to 13.998 mm/μs (0.020 in./μs to 0.551 in./μs) |
Resolution (selectable) | Low: 0.1 mm (0.01 in.) Standard: 0.01 mm (0.001 in.) High Resolution (optional): 0.001 mm (0.0001 in.) |
Transducer frequency range | Standard: 2.0 MHz to 30 MHz (-3 dB) High Penetration (optional): 0.50 MHz to 30 MHz (-3 dB) |
General | |
Operating temperature range | -10 °C to 50 °C (14 °F to 122 °F) |
Keypad | Sealed, color-coded keypad with tactile and audible feedback |
Case | Impact-resistant and water-resistant, gasketed case with sealed connectors. Designed for IP67. |
Dimensions (W x H x D) | Overall: 125 mm x 211 mm x 46 mm (4.92 in. x 8.31 in. x 1.82 in.) |
Weight | 0.814 kg (1.80 lb) |
Power supply | AC/DC adaptor, 24 V; lithium-ion battery 23.760 Wh; or 4 AA auxiliary batteries |
Battery life, lithium-ion | Operating time: minimum 12.6 h, 14 h typical, 14.7 h maximum Fast charge: 2 h to 3 h |
Standards | Designed for EN15317 |
Display | |
Color transflective VGA display | Liquid crystal display, display area 56.16 mm x 74.88 mm (2.2 in. x 2.95 in.) |
Rectification | Full wave, RF, half-wave positive, or half-wave negative |
Inputs/Outputs | |
USB | 1.0 client |
RS-232 | Yes |
Memory card | Maximum capacity: 2 GB External MicroSD memory card |
Video output | VGA output standard |
Internal Data logger | |
Data logger | The 38DL PLUS identifies, stores, recalls, clears, and transmits thickness readings, waveform images, and gage configuration information through the standard RS-232 serial port or USB port. |
Capacity | 475,000 thickness measurements or 20,000 waveforms with thickness measurements |
File names, IDs, and comments | 32-character file names and 20-character alphanumeric location codes with four comments per location |
File structures | Nine standard or custom application-specific file structures |
Reports | On-gage reporting of summary with statistics, Min./Max. with locations, Min. review, file comparison, and alarm report |
38DLP-OXIDE (U8147014): Code-activated Internal Oxide measurement software
38DLP-HR (U8147015): Code-activated High Resolution measurement software
38DLP-MM (U8147016): Code-activated Multilayer measurement software
38DLP-HP (U8147017): Code-activated High Penetration (low frequency) measurement software
38DLP/EW (U8778348): Three-year warranty
1/2XA/E110 (U8767104): Filter adaptor for E110-SB EMAT transducer
38-9F6 (U8840167): RS-232 cable
38-C-USB-IP67 (U8800998): USB cable for IP67 sealed operation
38DLP/RFS (U8780288):Foot switch, factory installed
HPV/C (U8840172): Digital caliper for thickness input for velocity measurements
38DLP-V-CC (U8780124): Cable for digital caliper
38DLP/BCW/NC (U8780289): Bar code reader
EPLTC-C-VGA-6 (U8840035):VGA output cable
MICROSD-ADP-2GB (U8779307): 2 GB External MicroSD memory card